Calculate Share Explore
oq-gem

Glossary for gem taxonomy

Authors: Luke Allen, Andrew Charleson, Svetlana Brzev, and Charles Scawthorn

This online Glossary explains around 400 terms contained in the GEM Building Taxonomy v 2.0 and nearly 700 images.

The terms have been listed in alphabetical and numerical order. Text description of each term is accompanied by illustrations (photos and/or drawings) where possible.

We welcome contributions in the form of photographs or images, illustrating glossary terms. If you have any questions you can also contact us at buildingtaxonomy@globalquakemodel.org


For at least one direction (across or along the building) the centre of rigidity or resistance is located anywhere beyond the half-way point between the centre of a typical floor plan and the side of the building.

Torsion is created when the centre of mass (CM) and the centre of rigidity or resistance (CR) in the building do not coincide - the distance between these two points is referred to as torsion eccentricity. CM is usually the geometric centre of the floor (in plan). Location of the CR depends on the characteristics of components of lateral load-resisting system (shear walls, moment frames, braced frames, etc.). Torsional effects can develop only in buildings with rigid diaphragms. Also large torsion eccentricities may not lead to torsion irregularity if lateral load-resisting structure normal to the torsion generating structure is widely-spaced in plan and strong.

Torsional forces in a building (FEMA, 2006)

How torsional effects develop in a building (FEMA 454)

TOR_FEMA454_2

Torsional effects can develop in buildings whose configuration is regular and symmetrical, however stiff structural components such as strairwells or elevator cores are offset with regards to the centre of mass. The photo shows a building in Vina del Mar that was severely damaged in the 1985 Llolleo, Chile earthquake, and the drawing shows its floor plan (FEMA 454)

TOR_FEMA454_1

Torsional effects develop in corner buildings or open front buildings, such as shown on the drawing (FEMA 454)

TOR_Canada_Brzev_1

An open front building (fire station), Vancouver, Canada (S. Brzev)

TOR_USA_NISEE_1TOR_USA_NRC_1

Collapse of the J.C. Penney building in the 1964 Anchorage, USA earthquake was attributed to torsional effects. Shear walls existed mostly along south and west facade. There were no shear walls in the north facade, which was covered by precast concrete panels, and there was a partial shear wall in the east facade. Torsional effects caused collapse of the east wall, and progressive collapse in the south and west walls. The photo shows east facade of the building after the earthquake, and the drawing shows a building plan (Courtesy of the NISEE, University of California, Berkeley, and U.S. National Research Council)

TOR_Pakistan_Tomazevic 1

A reinforced concrete frame building under construction was damaged in the 2005 Kashmir earthquake in Pakistan (see Figure 1). Columns in upper storeys suffered severe damage and permanent displacements (Figure 3) due to a decrease in the stiffness at upper storeys; this was caused by concrete block infill walls at the ground floor level. The damage in the columns was aggravated by the presence of a rigid stairwell in one of the corners (see Figure 1) which collapsed (see Figure 3).  The stairwell caused torsional effects in the building due to eccentricity between the centre of mass and the centre of resistance (M. Tomazevic)

TOR_New Zealand_Centeno_1

A reinforced concrete building was damaged in the 2011 Christchurch, New Zealand earthquake due to torsional effects. Lateral load resisting system consisted of reinforced concrete shear walls and elevator core along the east and north-west direction and reinforced concrete and masonry columns at the south, as shown on the plan. The damage was most pronounced in reinforced masonry  and reinforced concrete columns located at the southern facade of the building, as shown in the photo (J. Centeno)

TOR_Taiwan_NISEE_1

Building with an open first storey along street corner and walls along other exterior faces collapsed in the 1999 Chi Chi, Taiwan earthquake. The building tilted due to collapse of first storey columns, creating apparent torsional weakness (Courtesy of the NISEE, University of California, Berkeley, photo: J. Moehle)

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.