Calculate Share Explore
oq-gem

Glossary for gem taxonomy

Authors: Luke Allen, Andrew Charleson, Svetlana Brzev, and Charles Scawthorn

This online Glossary explains around 400 terms contained in the GEM Building Taxonomy v 2.0 and nearly 700 images.

The terms have been listed in alphabetical and numerical order. Text description of each term is accompanied by illustrations (photos and/or drawings) where possible.

We welcome contributions in the form of photographs or images, illustrating glossary terms. If you have any questions you can also contact us at buildingtaxonomy@globalquakemodel.org


The structure incorporates ductile design, where steel members or reinforcing are designed to undergo plastic deformation in over-load situations before failure under earthquake loads occurs in structural members or their connections. Provision of ductility is achieved by both providing a hierarchy of member strengths in a structural system (known as Capacity Design Approach) as well as special member detailing. For example, ductile moment frames will have columns stronger than the beams and shear force detailing will prevent shear failures of both beams and columns occurring before flexural yielding.

DUC_NICEE_Murty_2

The main objective of the Capacity Design Approach is to ensure that buildings perform in a ductile manner, that is, to avoid brittle failure and collapse in earthquakes. The designer needs to select structural components in which extensive deformation and damage may be expected, while the remaining portion of the structure must remain strong enough, or flexible enough, to sustain these forces and deformations. This is can be explained on an example of a chain, where ductile links represent locations at which significant plastic deformations are expected (ductile links), while brittle links represent other structural components. For example, in a reinforced concrete frame extensive deformations are expected in the beams (analogous to ductile links), while columns need to remain strong (analogous to brittle links) (illustration by C.V.R. Murty, Earthquake Tip 9, NICEE, India)

DUC_Murty_1

One of the design requirements for ductile performance of reinforced concrete moment frames is to ensure Strong Column-Weak Beam design concept - beams must be the weakest links (C.V.R. Murty, Earthquake Tip 9, NICEE, India)

DUC_FEMA451B_1

Plastic hinges (shown in red colour) are locations in a reinforced concrete or steel moment frame system where significant deformations and damage are expected to take place during a major earthquake (FEMA 451B, 2006)

DUC_FEMA451B_2

DUC_FEMA451B_3

Special reinforcement detailing provisions are critical for ductile performance of reinforced concrete moment frame systems. Confinement is supplied by closely spaced reinforcement, usually in the form of hoops or ties. Reinforced concrete frames with adequately confined columns performed well in past earthquakes (illustrations: FEMA 451B)

DUC_FEMA451B_4

DUC_Canada_Brzev_1

Ductile behaviour of steel moment frame structures can be achieved using Reduced Beam Section (also known as dogbone connection). The dogbone connection consists of trimming a portion of the steel beam flange in the region adjacent to the beam-to-column connection; this type of connection acts as a ductile fuse, and it forces yielding to occur within  the reduced section of the beam; see an I-shaped beam with dogbone connection ready for the construction, Canada (drawing: FEMA 355D, photo: S. Brzev)

DUC_FEMA306_1

Reinforced concrete and reinforced masonry walls with proper reinforcement amount and detailing are expected to show ductile seismic performance (FEMA 306, 1999)

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.